Datalogic Scanning D8330 Manuel D’Utilisation

Page de 212
POWERSCAN
®
 D8330/M8300 
158 
 
 
5.7.3 
Interdigit Control 
 
The interdigit control parameter verifies the interdigit spacing for code families  
Code 39 and Codabar. 
 
 
5.8  ADVANCED FORMATTING 
 
5.8.1 
Match Conditions 
 
Selecting an Advanced Formatting and specifying a Match restriction (Code Type, 
Code Length, Predefined Characters) the code will be transmitted according to the 
order of the defined formats. 
 
For example, defining 2 formats where: 
• 
Format 1: Match Code type = Code128 
•  Format 2: Match Code length = 15 and Match with Predefined Characters 
“DATA” 
a Code128 “DATA:12345ABCDE” with code length 15 will be formatted following the 
Format 1. 
 
To send the same code with the Format 2 it is necessary to invert the format order as 
follows: 
•  Format 1: Match Code length = 15 and Match with Predefined Characters 
“DATA” 
• 
Format 2: Match Code type = Code128 
 
 
5.9  RADIO PARAMETERS (M8300 SERIES ONLY) 
 
5.9.1 
Radio Protocol Timeout 
 
This parameter sets the valid time to wait before transmission between the M8300 
series reader and BC-80X0 cradle is considered failed. 
 
This parameter should be set taking into consideration the radio traffic (number of 
readers in the same area). 
 
If the RS-232 interface is used with ACK/NACK enabled, this parameter should be at 
least equal to the RX Timeout parameter for low traffic environments. It should be 
increased if there are many readers in the same area. 
 
It can be set between 2 and 19 seconds.