5.9.2 
Radio RX Timeout 
 
When the scanner is used in a standalone layout (point-to-point or with multiple 
readers) it can be configured to receive “asynchronous” messages from the host at 
any time. 
 
There are two modes which can enable the scanner to receive messages from the 
host: 
1)  Enable “2 way” Communication Protocol – After the transmission of each 
barcode, the scanner waits for an acknowledgement from the host
. A 
message can be sent by the host accompanying this acknowledgement, or 
in place of it, to display something on the screen or execute a command 
(such as sound a beep sequence, turn an LED on or off, etc.). If no 
acknowledgement or message is received from the host within a 
programmable timeout duration, the radio will be switched off and an “error 
transmission” beep will be sounded. 
2)  Independent of the Selected Protocol – The scanner can be configured to 
keep the radio receiver “awake” for a defined period of time following each 
transmission. Any message coming from the host1 before expiration of the 
timeout is accepted. The parameter “Radio RX Timeout” is used for 
specifying how long the scanner have to wait for a message after receiving 
each code transmission. 
In this mode, the radio can also be “awakened” by pressing the trigger. 
The scanner can receive a message only if it is linked to the Base (i.e. the 
scanner has been joined to the Base and has had at last one “valid” 
transmission after the last power-on). Setting the “Radio RX timeout” value 
to “00” specifies that the radio never goes into sleep mode (always awake 
Æ
 the scanner can receive a message at any time). Choosing this setting 
will, of course, consume battery life more quickly. 
 
1
See Section 6.1 for Host to Scanner message formatting. 
 
5.9.3 
Power-Off Timeout 
 
If this command is enabled, after the desired timeout in hours, the PowerScan
®
 
batteries are disconnected and all power consumption ceases. To restore power, 
press the trigger once. The reader will now be ready to read codes. 
Power-off does not affect configuration parameters.