Step 3: (Gas Dryer Only) Connect Gas 
Supply Pipe
For further assistance, refer to section on Gas 
Requirements
.
1. Make certain dryer is equipped for use with the 
type of gas in laundry room. Dryer is equipped at 
the factory for Natural Gas with a 3/8" N.P.T. 
gas connection.
2. Remove the shipping cap from the gas 
connection at the rear of the dryer. Make sure 
you do not damage the pipe threads when 
removing the cap.
3. Connect to gas supply pipe.
4. Tighten all connections securely. Turn on gas 
and check all pipe connections (internal & 
external) for gas leaks with a non-corrosive leak 
detection fluid.
5. For L.P. (Liquefied Petroleum) gas connection, 
refer to section on Gas Requirements.
Figure 11 
D233I
1
New Stainless Steel Flexible Connector – 
Use only if allowed by local codes 
(Use Design A.G.A. Certified Connector)
4
Black Iron Pipe
Shorter than 20' (6.1 m) – Use 3/8" pipe
Longer than 20' (6.1 m) – Use 1/2" pipe
2
1/8" N.P.T. Pipe Plug 
(For checking inlet gas pressure)
5
3/8" N.P.T. Gas Connection
3
Equipment Shut-Off Valve – Installed within 6' 
(1.8 m) of dryer
D233I
1
5
4
2
3