ARRI 416 Manuel D’Utilisation

Page de 240
7.4 Attaching the Magazine 
•  Move the magazine release lever safety catch to the 
open position 
a
photo
•  Press down the magazine release lever 
a
photo
 and 
remove the magazine opening cover.
•  Remove the loop protector from the magazine.
•  Place the magazine’s throat in the camera opening and 
slide the magazine forward into the camera until it latches.
•  Flip the magazine release lever safety catch forward to 
prevent accidental release of the magazine.
•  Press the “PHASE” button for a couple of seconds to 
inch the film.
Note: 
After a new magazine has been attached or after 
camera power has been turned on, you should 
always push the “PHASE” button to perform a loop 
check (the display shows “LooP“). This takes about 
2 seconds and will engage the pull down claw, 
check loop size and centre the loop properly.
Note: 
If the loop check finds that the loop is too short for 
safe camera performance the message “Error 
LooP.S“ will show in the camera display. The camera 
is not ready and will not run. If the loop check 
finds that the loop is too long for safe camera 
performance the message “Error LooP.L“ will show 
in the camera display. The camera is not ready 
and will not run. 
Camera
Body
release lever
release lever 
safety catch