Monessen Hearth MJ27PR Manuel D’Utilisation

Page de 40
86D0024
13
FP1998
heat resist mantel
Hood
Heater in 
Fireplace or 
Firebox
8" or More of 
Heat Resis-
tant Materials
FP1998
CLEARANCES and HEIGHT REQUIREMENTS
Figure 6 - Measuring Heat Resistant Material for Mantel
Heat resistant material (minimum requirements) with wooden mantel or other combustible projection:
To install the heater with a wooden mantel, shelf or other combustible projection above, first measure the heat 
resistant material shown in Figure 6, then refer to Table B. 
TABLE B - Heat Resistant Material Heights and Mantel Location
 
Heat Resistant  
Requirements for Safe Installation with Wood 
 
Material 
Mantel, Shelf or Other Combustible Projection
  Measurement 
MJ27
  12" or more 
Hood not required. Observe profile (side elevations)  
   
 
shown on Page 14, Figure 8.
  8" to less than 12" 
Install hood and observe profiles shown on Page 14,
 
Figure 7
OR extend heat resistant material to at least  
   
 
12" and observe profiles shown on Page 14, Figure 8.
  Less than 8" 
Extend heat resistant material to at least 8", install  
   
 
hood and observe profiles shown on Page 14, Figure
 
7
OR extend heat resistant material to at least 12"  
   
 
and observe profiles on Page 14, Figure 8.