Regency Wraps I2400M Manuel D’Utilisation

Page de 20
Regency I2400M
11
Ground
Fan
Fan
Ground
Green
Neutral
Live
White
Fan
Switch
Manual/
Auto
Switch
Black
Black
High
(Black)
Low
(Red)
Black
Fan Thermodisc
(normally open)
120V AC
60 Hz
Thermo
Switch
Sensor
INSTALLATION
STEP-BY-STEP INSTALLATION
OF THE FAN/BLOWER
Blower/Fan Wiring Diagram
3)  Slide the supports into the clips. The tension 
holding the clips in place may be adjusted by 
increasing or decreasing the offset spacing 
of the clips.
4)  Ensure that the power cord is not in 
contact with any hot stove surfaces. 
 
NOTE: DO NOT ROUTE POWER CORD 
UNDER OR IN FRONT OF UNIT.
 
5)  Push the Regency logo plate into the two 
holes in the front bottom left corner of the 
fan.
Your fan should only be installed once the unit is 
in place in order to prevent any damage to the 
fan. To attach, follow the instructions provided 
with the fan.  Make sure to install the rubber 
grommet to the fan housing before it is installed 
on the insert.  
1)  Remove the protective covering from the 
brass trim on the fan.
2)  Align the fan support with the offset clip on 
the bottom of the ashlip. 
CAUTION:   Label all wires prior 
to disconnection when servic-
ing controls. Wiring errors can 
cause improper and dangerous 
operation.
WARNING: 
Electrical Grounding Instructions
This appliance is equipped with a 
three pronged (grounding) plug for 
your protection against shock hazard 
and should be plugged directly into 
a properly grounded three-prong 
receptacle. Do not cut or remove the 
grounding prong from this plug.
Do not turn fan ON until your insert has 
reached operating temperature or at least 
30 minutes after starting fi re.