Heat Controller BG-123G Manuel D’Utilisation

Page de 36
 
 
PROBLEM 
POSSIBLE CAUSE 
TO CORRECT 
Fuse blown or circuit tripped. 
Replace fuse, reset breaker. If repeats, 
check fuse or breaker size. Check for shorts 
in unit wiring and components. 
Power cord not plugged in. 
Set switch correctly.   
System switch in "Off" position. 
Test for continuity in each switch position. 
Inoperative system switch. 
Check wiring and connections. 
Unit does 
not run. 
Loose or disconnected wiring at 
switch or other components.   
Reconnect per wiring diagram. 
Thermostat contacts stuck. 
Replace thermostat. 
Thermostat set at coldest point. 
Turn to higher temperature setting to see if 
the unit cycles off.   
Incorrect wiring. 
Refer to appropriate wiring diagram. 
Thermostat 
does not 
turn unit off. 
Unit undersized for area to be 
cooled. 
Refer to Sizing Chart.   
Dirty filter. 
Clean as recommended in Owner’s Manual. 
Restricted air flow. 
Check for dirty or obstructed coil - clean as 
required or remove obsticales. 
Inoperative thermostat. 
Test for shorted thermostat or stuck 
contacts. 
Short of refrigerant. 
De-ice coil and check for leak. 
Inoperative fan motor. 
Test fan motor and replace if inoperative. 
Evaporator 
coil freezes 
up.  
Partially restricted capillary. 
De-ice coil. Check temperature differential 
across coil. Touch test coil return bends for 
same temperature. Test for low running 
current.  
Excessive heat load. 
Unit undersized. Test cooling performance 
of unit. Replace with larger unit. 
Restriction in line. 
Check for partially iced coil. Check 
temperature split across coil. 
Refrigerant leak. 
Check for oil at silver soldered connections. 
Check for partially iced coil. Check split across 
coil. Check for low running amperage.   
Thermostat contacts stuck 
Check operation of thermostat. Replace if 
contacts remain closed. 
Compressor 
runs 
continually, 
does not 
cycle off.   
Thermostat incorrectly wired. 
Refer to appropriate wiring diagram. 
 
 
 
 
 
 
Service Manual
Room Air Conditioner with R-410A
Heat Controller, Inc.
31