• Phase Monitors - Designed to prevent unit damage. The 
phase monitor will shut the unit down in an out-of phase 
condition. (Standard on units with Scroll Compressors.)
• Coil Guard - Customers can purchase a coil guard kit to 
protect the condenser coil from damage. Additionally, this 
kit stops animals and foreign objects from entering the 
space between the inner condenser coil and the main 
cabinet. This is not a hail guard kit.
• Dirty Filter Switch - This kit includes a differential 
pressure switch that energizes the fault light on the unit 
thermostat, indicating that there is an abnormally high 
pressure drop across the filters. Factory installed option or 
field installed accessory.
• Technicoat Condenser Coils - The condenser coils are 
coated with a phenolic coating for protection against 
corrosion due to harsh environments.
• Technicoat Evaporator Coil - The evaporator coils are 
coated with a phenolic coating for protection against 
corrosion due to harsh environments.
• Hot Gas Bypass - Allows operation during low load 
conditions while avoiding coil frosting and damage to 
compressor. When suction pressure falls below valve 
setpoint, the valve modulates hot gas to the inlet of the 
evaporator. HGBP is standard on all units with VAV and 
optional with constant-volume units.
Control Options
• Simplicity
®
 INTELLI-Comfort™ Control communicates 
on a MODBUS RTU protocol network - The York
®
 
Simplicity
®
 INTELLI-Comfort™ control is factory installed. It 
includes a supply air sensor, a return air sensor, and an 
outside air sensor. There are provisions for a field installed 
dirty filter indicator switch, an air-proving switch, an Outside 
Air Humidity sensor, a Return Air Humidity sensor, an 
Inside IAQ sensor, and an Outside Air IAQ sensor. 
Construction mode operation, 365-day real time clock with 
7 day programming plus holiday scheduling is built-in. Two 
different modes of demand ventilation are achieved through 
the INTELLI-Comfort™ using CO
2
 sensors. It uses an 
inside CO
2
 sensor to perform Demand Ventilation. It can 
also use an Outside CO
2
 sensor to perform Differential 
Demand Ventilation. It uses a Patented Comfort Ventilation 
algorithm to provide comfortable ventilation air 
temperature. The patented economizer-loading algorithm 
will protect the equipment when harsh operating conditions 
exist. Humidity in the occupied space or return duct can be 
monitored and controlled via humidity sensors and the on-
board connection for hot gas re-heat system. It uses the 
INTELLI-Start™ algorithm to maximize energy savings by 
recovering the building from the Unoccupied Setpoints to 
the Occupied Setpoints just in time for the Occupied Time 
Period to begin. The Simplicity
®
 INTELLI-Comfort™ 
balances space temperature, ventilation air temperature, 
CO
2
 and humidity for ultimate comfort.
• Simplicity
®
 INTELLI-Comfort™ with Simplicity®LINC
Control - The York® Simplicity
®
 INTELLI-Comfort™ with 
Simplicity®LINC control is factory installed. It includes all 
the features of the INTELLI-Comfort™ control with an 
additional control to translate communications from 
MODBUS to the BACnet MSTP protocol.
• Novar® BAS Control - The Novar® building automation 
system controller is factory installed. Includes supply air 
sensor, return air sensor, dirty filter indicator switch, and 
air proving switch.
• Johnson Controls BAS Control - The Johnson Control 
YK-UNT-1126 building automation system controller is 
factory installed. Includes supply air sensor, return air 
sensor, dirty filter indicator switch, and air proving switch.
• CPC BAS Control - The Computer Process Controls 
Model 810-3060 ARTC Advanced Rooftop building 
automation system controller is factory installed. Includes 
supply air sensor, return air sensor, dirty filter indicator 
switch and air proving switch.
• Honeywell BAS Control - The Honeywell W7750C 
building automation system controller is factory installed. 
Includes air supply sensor, return air sensor, dirty filter 
indicator switch, and air proving switch.
• York Commercial Comfort System (YCCS) - Provides 
rooftop system integration for YCCS single zone and 
change-over bypass systems.
Field Installed Accessories
YORK
®
 offers several equipment accessories for field 
installation, for the Predator
®
 
line.
• Downflow Economizer - (With barometric relief) - The 
economizer is provided with a single enthalpy input. The 
economizer is 2% low leakage type. The economizer has 
spring return, fully modulating damper actuators and is 
capable of introducing up to 100% outdoor air. As the 
outdoor air intake dampers open, the return air dampers 
close. The changeover from mechanical refrigeration to 
economizer operation is regulated by the standard single 
enthalpy input. There is an optional input dual dry bulb 
sensor available. To meet regulated air standards, the 
economizer control accepts an optional CO
2
 
input for
 
demand ventilation. With single enthalpy input, the 
economizer control monitors outdoor air. The dual enthalpy 
kit provides a second input used to monitor the return air. 
With a dual input kit installed, the economizer control 
compares the values of the two enthalpy or temperature 
inputs and positions the dampers to provide the maximum 
efficiency possible.
• Horizontal Economizer (Without barometric relief) 
All features of the downflow economizer exist except you 
must order the duct mount barometric relief separately. 
You must order a 1EH0408 if you are installing a 
power exhaust. You can order a 1RD0411 Barometric 
Relief for horizontal flow economizer.
Factory-installed smoke detectors may be subjected to 
extreme temperatures during "off" times due to outside air 
infiltration. These smoke detectors have an operational 
limit of -4°F to 158°F. Smoke detectors installed in areas 
that could be outside this range will have to be relocated to 
prevent false alarms.