   GAS CONNECTION 
 
Check gas type. Use only the type of 
gas  indicated on the valve rating 
plate. If the type of gas listed on the 
plate is not your type of gas 
supply,DO NOT INSTALL. Contact 
your dealer for proper model. 
Always use an external regulator for 
all LP heaters to reduce the supply 
tank pressure to a maximum of 13" 
W.C. This is in addition to the 
regulator furnished with the heater. 
 
Warning: Connection directly to an 
unregulated LP tank can cause an 
explosion. 
 
The normal gas connection is 3/8" 
NPT made at the right side facing the 
log set. If a left side connection is 
desired, the connecting pipe may be 
routed under the  rear of the burner 
base to terminate at the right hand 
side for connection to the inlet of the 
valve. 
 
NOTE:  The connecting  pipe must be 
internally treated for protection from 
sulfur compounds  if copper tubing is 
used for natural gas. 
Test for leaks using a solution of soap 
and water after completing the 
connection.  DO NOT USE OPEN 
FLAME. 
 
CLEARANCES TO 
COMBUSTIBLES 
(Vent-Free Operation Only) 
 
WARNING:
  Maintain the 
minimum clearances. If you can, 
provide greater clearances from 
floor, ceiling, and adjoining side 
and back walls. 
 
Carefully follow the instructions 
below. This stove is a freestanding 
unit designed to set directly on the 
floor. Do not place stove directly on 
carpeting, vinyl tile, or any 
combustible material other than 
wood. The stove must set on a metal 
or wood panel extending the full 
width and depth of the appliance. 
IMPORTANT:
 You must maintain 
minimum wall and ceiling clearances 
during installation. The minimum 
clearances are shown in Figure 4. 
Measure from outermost point of stove 
top. 
 
Minimum Wall and Ceiling 
Clearances (See Figure 4) 
 
A. Clearances from outermost 
point of stove top to any 
combustible side wall should 
not be less than 4 inches. 
B. Clearances from outermost 
point of stove top to any 
combustible back wall should 
not be less than 4 inches 
(Includes Corner Installations). 
C.  Clearances from the stove top 
to the ceiling should not be less 
than 48 inches. 
 
 
 
 
 
INSTALLATION
 
 
NOTICE: 
This heater is intended 
for use as supplemental heat. Use this 
heater along with your primary 
heating system. Do not install this 
heater as your primary heat source. Do 
not run ceiling fan while heater is 
running. In the event of a power 
outage, you can use this heater as your 
primary heat source. 
 
WARNING
:   A qualified service 
person must install heater. Follow 
all local codes. 
 
WARNING:
  Never install the 
heater 
• 
in a bedroom or bathroom 
• 
in a recreational vehicle 
• 
where curtains, furniture, 
clothing, or other flammable 
objects are less than 48 inches 
from the front, top, or sides of 
the heater 
• 
in high traffic areas 
• 
in windy or drafty areas 
 
CAUTION:
 This heater creates 
warm air currents. These currents 
move heat to wall surfaces next to 
heater. Installing heater next to vinyl 
or cloth wall coverings or operating 
heater where impurities (such as 
tobacco smoke, aromatic candles, 
cleaning fluids, oil or kerosene lamps, 
etc.) in the air exist, may discolor 
walls. 
 
IMPORTANT:
  Vent-free heaters 
add moisture to the air. Although this 
is beneficial, installing heater in rooms 
without enough ventilation air may 
cause mildew to form from too much 
moisture. See Air for Combustion and 
Ventilation,
 pages 4 through 5. 
 
Maintain adequate clearances for 
accessibility for the purpose of 
servicing and proper operation.  
CEILING 
48" MINIMUM 
     4" 
MINIMUM 
     4" 
MINIMUM 
SIDE 
WALL 
FRONT VIEW 
SIDE 
WALL 
TOP VIEW 
BACK WALL 
SIDE 
WALL 
SIDE 
WALL 
CORNER 
WALL 
WALL 
4" MINIMUM 
4" MINIMUM 
4" MINIMUM 
4"  
MINIMUM 
 FIGURE 4 -  MINIMUM CLEARANCES 
TO WALLS AND CEILING  
 