FRONT ACCESS TO  
(SIT) MILLIVOLT     
VALVE 
 
When performing pressure checks or wiring 
accessories such as remote control, or wall 
mounting thermostats it will be necessary to 
access the front of the valve body. 
To access the front of the valve body, you 
must remove the face plate from the control 
bracket. To remove the face plate you will 
need to remove the two (2) Phillip head 
screws which attach it. After removing the 
screws, pull the face plate back from the 
unit. This will give you the access you need. 
When finished reattach the face plate to the 
control bracket with the screws you  re-
moved before operating the unit. 
 
 
 
          
      CAUTION
 
If unit has been in operation, allow the 
unit time to cool before touching. Failure 
to do so may result in personal injury.  
CONTROL BRACKET 
FACE PLATE 
SCREWS 
(SIT MILLIVOLT VALVE WITHOUT FACE PLATE)  
(SIT) MILLIVOLT VALVE WITH FACE PLATE ON 
 
 
 
 
 
NOTE:  To ensure proper 
connection of switch refer 
to page 32. Make sure the 
proper wires are used for 
thermostat and remote 
control connections, if not 
installed correctly  the 
unit will not operate.  
16