Lucent Technologies Release 7 Manuel D’Utilisation
DEFINITY Enterprise Communications Server Release 7
Maintenance for R7r
Maintenance for R7r
555-230-126
Issue 4
June 1999
Maintenance Object Repair Procedures
9-747
E-DIG-STA (Emulated Digital Line)
9
Notes:
a. Maintenance personnel have busied out the port in question. Make sure
that the port is released from busyout by using the release port
UUCSSpp command.
UUCSSpp command.
b. The circuit pack has been removed or has been insane for more than 21
minutes. To clear the error, reinsert or replace the circuit pack.
c. Problems transmitting to the voice terminal. This problem can be caused
by defective wiring, which can cause varying degrees of problems on
different types of sets. Sets such as the 7410 appear to be more
susceptible to wiring problems than others.
different types of sets. Sets such as the 7410 appear to be more
susceptible to wiring problems than others.
d. An in-link maintenance error has generated an off-board warning due to
some problem with the link to the voice terminal. This can be ignored if no
user complaints are received. Otherwise, make sure the voice terminal is
connected, check for defective wiring, check for a defective voice
terminal, and move voice terminal to a jack that is closer to the switch
(number of feet of wiring between the jack and the switch). If the problem
still exists, replace the circuit pack. Once the problem has been resolved,
the alarm is retired after a predetermined amount of time.
user complaints are received. Otherwise, make sure the voice terminal is
connected, check for defective wiring, check for a defective voice
terminal, and move voice terminal to a jack that is closer to the switch
(number of feet of wiring between the jack and the switch). If the problem
still exists, replace the circuit pack. Once the problem has been resolved,
the alarm is retired after a predetermined amount of time.
e. The local loop test failed. Each failure increments the counter by 1 when
the local loop test fails. The counter is decremented when the loop test
passes. When the counter reaches a threshold of 3, an on-board MINOR
alarm is raised.
passes. When the counter reaches a threshold of 3, an on-board MINOR
alarm is raised.
f. The NPE Crosstalk test failed. The counter is incremented by 1 when the
NPE Crosstalk test fails. The counter is decremented by 1 when the NPE
Crosstalk test passes. When the counter reaches a threshold of 3, an
on-board MINOR alarm is raised and the board is taken out of service.
Crosstalk test passes. When the counter reaches a threshold of 3, an
on-board MINOR alarm is raised and the board is taken out of service.
2305 (g)
32770
None
3840 (h)
40965
None
3841 (i)
41029
None
2304 (j)
None
1.
Run the Short Test Sequence first. If all tests pass, run the Long Test Sequence. Refer to the
appropriate test description and follow the recommended procedures.
appropriate test description and follow the recommended procedures.
2.
Major alarms may be downgraded to Warning alarms based on the value used in the set options
command.
command.
Table 9-288.
Digital Line Error Log Entries - E-DIG-STA — Continued
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
Continued on next page