RAD Data comm ASM-60 Manuel D’Utilisation

Page de 74
Chapter 4  Management from a Terminal 
ASM-60 Installation and Operation Manual 
4-2 
Navigating the Management Menus
 
 
Table 4-1.  Control Port Control Signals 
Control Line 
Interface Type 
 
DCE DTE 
CTS Out  Not 
Used 
DCD Out  Out 
DSR Out  Out 
DTR In 
In 
RI Not 
Used 
In 
RTS In 
In 
Data Terminal Ready (DTR) 
When connected and turned on, the terminal sets the DTR line ON (active) to gain 
control over ASM-60 and starts a configuration or monitoring session. 
Initiating a Control Session 
➤  To initiate a control session: 
1.  Connect the terminal cable to the CONTROL DCE connector of ASM-60. 
2.  Turn the control terminal on.  
3.  Configure the terminal to the default communication parameters: 19.2 kbps, 
one start bit, eight data bits, no parity, one stop bit, VT100. 
4.  Select the full-duplex mode. 
5.  Turn the terminal echo off  
You are now ready to start a control session. 
4.2  Navigating the Management Menus 
This section provides a general description of the software menu operation and 
conventions for navigating the menus.  
Figure 4-1 shows a map of the management menus in the ASM-60 embedded 
software. 
➤  To choose an option: 
•  Type the number corresponding to the option, and press <Enter>
The screen for the selected option is displayed. 
➤  To correct an erroneous entry: 
•  Press <Backspace> to clear the error, then enter the correct characters. 
or 
Press <Esc> to exit the current menu, and then return to the menu to 
re-enter the required value.