Installing the SEHI
SEHI User’s Guide
4-3
4.3.1
Tabletop or Shelf Installation
This section provides guidelines for installation on a tabletop or shelf. 
Tabletop and shelf installations must be within reach of the network 
cabling and meet the requirements listed below:
A single phase grounded power receptacle that meets the power supply 
requirements listed in Chapter 3 under Power Supply Requirements 
must be located within seven feet of the location.
In a shelf installation, the shelf must be able to support 30 pounds of 
static weight for each device in the stack. 
Maintain a temperature of between 5
°
C (41
°
F) and 40
°
C (104
°
F) at 
the site with fluctuations of less than 10
°
C (18
°
F) per hour.
For a tabletop or shelf installation, locate the SEHI within seven feet of its 
power source and with an unrestricted free surface area as shown in 
Figure 4-2.
Figure 4-2
Tabletop or Shelf Installation
If the installation requires that the SEHI is to be stacked, proceed to 
Section 4.3.3. Otherwise, continue by connecting power as described in 
Section 4.4.
!
C AUT IO N
In order to allow for proper cooling, there must be a two-inch 
clearance on either side and the back of the unit.
21 IN.
6 IN.
18 IN.
0165203
7 FT
HubSTACK 
10BASE-FL HUB 
WITH
 LANVIEW® 
SECURE
SEHI-22FL
E
1
RCV
LNK
12  11  10  9  8  7   6   5   4   3   2   1
PWR
CPU
CLN
RX
TX
RX
TX
RX
TX
RX
TX
RX
TX
RX
TX
RX
TX
RX
TX
RX
TX
RX
TX
RX
TX
RX
TX
1
2
3
4
5
6
7
8
9
10
11
12
EPIM 1
RESET
COM
SEHI Book  Page 3  Friday, April 19, 1996  10:46 AM