Chapter 6: Troubleshooting
6-2
SEHI User’s Guide
2. If the remote station is ready and the LNK LED is on, but no data 
passes through the port, one of the following two conditions may exist:
Network management disabled the port. 
The port is segmented either because the collision detector was on 
for more than 110 
µ
s or the SEHI detected more than 32 
consecutive collisions on the attached segment. The affected port 
remains segmented until a good packet is transmitted/received 
without collisions.
If the LNK LED is still off, contact Cabletron Systems Technical 
Support.
6.2
USING LANVIEW
The SEHI incorporates the Cabletron Systems LANVIEW status 
monitoring and diagnostics system. LANVIEW LEDs help diagnose 
problems such as power failure or cable fault. The SEHI uses the 
following LANVIEW LEDs:
PWR, for power status
CPU, for board status
RCV (Receive), LNK (Link), and CLN (Collision) for Ethernet 
status.
Figure 6-1 provides a quick reference chart of LED locations and 
definitions. This chapter also includes a detailed description of each LED. 