Cabletron Systems SEHI-22FL Mode D'Emploi

Page de 85
Chapter 6: Troubleshooting
6-4
SEHI User’s Guide
CLN
This red LED indicates that a collision has occurred on one of the ports.
RCV
When a yellow RCV LED flashes, it indicates that the SEHI is receiving 
data packets from the associated port segment. Each SEHI port has a 
corresponding RCV LED. The network RCV port LEDs are labeled 1-12 
and the EPIM-1 RCV port LED is labeled E-1.
LNK
When a green LNK LED is on, it indicates an established link between 
the associated port and the device at the other end of the segment. The 
LNK LED remains on as long as a link is maintained. Each SEHI 
Network Port (ports 1–12) has a corresponding LNK LED.
6.3
USING THE RESET BUTTON
The SEHI incorporates a recessed RESET button. See Figure 6-1. The 
RESET button initializes the SEHI processor. This button does NOT 
initialize Non-Volatile Random Access Memory (NVRAM), the 
nonvolatile random access memory where the SEHI stores network 
management parameters.
To use the RESET button, use a pen or pencil to press the button. When 
this is done, the SEHI initializes itself.
SEHI Book  Page 4  Friday, April 19, 1996  10:46 AM