Setting the NVRAM Switch
SEHI User’s Guide
6-5
6.4
SETTING THE NVRAM SWITCH
The SEHI uses NVRAM (Non-Volatile Random Access Memory) to store 
user-entered parameters such as IP address and Community Names. To 
reset these parameters to the factory defaults, refer to Figure 6-2 and 
perform the following steps:
1. With the power ON and using a non-metallic tool, move the NVRAM 
switch to the UP position.
2. Press the RESET switch located on the front panel.
3. Wait until the unit boots (approximately 12 seconds).
4. Return the NVRAM switch to the DOWN position.
Figure 6-2
NVRAM Switch Location
To prevent the possibility of electrical shock, 
do not
 remove the 
chassis cover to access the NVRAM switch, and use only a 
non-metallic
 tool when moving the NVRAM switch.
!
C AUT IO N
Failure to return the NVRAM switch to the DOWN position 
results in loss of user-entered parameters upon power 
shutdown and restart. The SEHI clears NVRAM if the unit is 
restarted with the switch in the UP position.
Rear of Chassis
NVRAM Switch located behind grating
165215
SEHI Book  Page 5  Friday, April 19, 1996  10:46 AM