Lucent Technologies 555-233-115 Manuel D’Utilisation
DEFINITY Enterprise Communications Server Release 8.2
Upgrades and Additions for R8r
Upgrades and Additions for R8r
555-233-115
Issue 1
April 2000
Troubleshooting an Upgrade
B-12
Troubleshooting Release 8 Upgrades
B
Software Incompatibility
If these procedures do not clear the corruption problem, then the software
versions may be incompatible. You may need to upgrade to an interim software
version before upgrading to the final software version.
versions may be incompatible. You may need to upgrade to an interim software
version before upgrading to the final software version.
1. Consult the remediation that came with the upgrade software.
2. Contact your Lucent Technologies representative for this information.
Re-install the ISDN-PRI Links (Only for Failed
Upgrades)
Upgrades)
If your upgrade failed and you need to re-install the ISDN-PRI links, use this
procedure.
procedure.
1. Type add data-module [PI ext] and press
Enter
.
2. Type the information in the fields based on the information that you
entered earlier.
3. Type change communication-interface links and press
Enter
.
4. Type the information in the fields based on the information that you
entered earlier with one exception. Leave the
Enable
field setting as it is.
5. Type change communication-interface processor-channels and press
Enter
.
6. Type the information in the fields based on the information that you
entered earlier.
7. Type change communication-interface links and press
Enter
.
8. Type the information in the
Enable
field based on the information that you
entered earlier.
9. Type save translation and press
Enter
.