Troubleshooting  an Upgrade 
B-12
Troubleshooting Release 8 Upgrades 
B
Software Incompatibility
If these procedures do not clear the corruption problem, then the software 
versions may be incompatible. You may need to upgrade to an interim software 
version before upgrading to the final software version.
1. Consult the remediation that came with the upgrade software.
2. Contact your Lucent Technologies representative for this information.
Re-install the ISDN-PRI Links (Only for Failed 
Upgrades)
If your upgrade failed and you need to re-install the ISDN-PRI links, use this 
procedure. 
1. Type add data-module [PI ext] and press 
Enter
.
2. Type the information in the fields based on the information that you 
entered earlier.
3. Type change communication-interface links and press 
Enter
.
4. Type the information in the fields based on the information that you 
entered earlier with one exception. Leave the 
Enable
 field setting as it is.
5. Type change communication-interface processor-channels and press 
Enter
.
6. Type the information in the fields based on the information that you 
entered earlier.
7. Type change communication-interface links and press 
Enter
.
8. Type the information in the 
Enable
 field based on the information that you 
entered earlier.
9. Type save translation and press 
Enter
.