Bunn 41343 Manuel D’Utilisation

Page de 40
Page 26
PROGRAMMING FUNCTIONS - (cont.)
SET PULSE BREW - BY EXAMPLE
 
This function allows adjustment of the pulse brew 
by first observing the flow of water for on and off 
times. 
Procedure to set pulse brew by example:
NOTE: The procedure to enter the Pulse Brew Function  
(Page 21) must be performed prior to following 
the steps listed below.
1.  Press and release YES. The display should now 
read SET BY EXAMPLE.
2.  Press and release YES. The display will read 
CONTAINER READY?
  Place a container under the sprayhead. Place a 
brew funnel containing a filter and grounds on top 
of the container so that the spray and coffee bed 
can be viewed. (See Fig. 1)
3.  Choose the batch size to be set by pressing the pad 
next to the indicator light on the brew side. The 
batch size indicator selected will be flashing.
4.  If everything is in place, press YES in the CON-
TAINER READY? screen. The display will read 
PRESS BREW TO SET 1st ON-TIME.
5.  Press and release the BREW switch. The brew 
water will start to flow into the funnel and the water 
level will rise.
6.  Watch the flow of water. When it reaches the 
desired level in the funnel, press and release the  
BREW switch again to end the 1ST ON TIME.
7.  The spray will stop and the brew funnel will start 
to empty. When the water level in the funnel drains 
to the desired level, press BREW switch again to 
end the OFF-TIME. This also begins the spray of 
water for the final setting.
8.  The brew water will begin again and the water level 
in the funnel will rise. Watch the flow of water. 
When it reaches the desired level, press the BREW 
switch to end the LAST ON TIME.(e)
9.  The display should now show the 1st, off and last 
times for the batch size just programmed. After a 
5 second delay, the display will read 3 BATCHES 
DONE? 
10. When finished press YES in 3 BATCHES DONE? 
The display will then read SET PREINFUSION.
11. Press and release the ON/OFF switch (either on 
DUAL brewers)located on the front switch panel 
to exit the UNITS function and return to the MAIN 
SCREEN.
P2288
FIG. 1
SET PULSE BREW ?
NO                     YES
SET BY EXAMPLE ?
NO                     YES
CONTAINER RDY ?
NO                     YES
PRESS BREW TO
SET  1st ON-TIME
3 BATCHES DONE ?
NO                     YES
PRESS BREW TO
END  1st ON-TIME
PRESS BREW TO
END  OFF-TIME
PRESS BREW TO
END  LAST ON-TIME
EXIT TO 
NEXT FUNCTION
SCREEN
41343 080108