Procedure to set the sensitivity threshold of the 
refill circuit:
NOTE: Make sure the water in the tank is touching 
the refill probe.
1.  Press and hold upper right hidden switch until the 
display reads UNITS. Release switch.  Press and 
release upper right hidden switch until the display 
reads REFILL and shows a number on both sides 
of the word.
2.  To adjust the threshold setting, press (-) to de-
crease, or (+) to increase the setting.
NOTE: Always make sure that the number on the right 
is larger than the number on the left when water is in 
contact with the refill probe in the tank.
3.  When finished, press and release DONE. This saves 
the new setting and advances to the next function 
screen:
 
SPRY OZ/M (SINGLE brewers)
PROGRAMMING FUNCTIONS - (cont.)
 
L SPRY OZ/M (DUAL brewers). Another alternative 
is to press and release the ON/OFF switch (either on 
DUAL brewers) located on the front switch panel 
to exit REFILL and return to the MAIN SCREEN.
SPRAY OZ/M
 
This function allows the operator to view or to enter 
the actual flow rate coming out of the sprayhead. This 
is NOT used to change the actual flow rate, but to tell 
the internal controller how fast the water is flowing. 
The unit of measure is ounces per minute (Oz/M).
Procedure to set ready temperature:
1.  Press and hold upper right hidden switch until the 
display reads 
UNITS. Release switch.  Press and 
release upper right hidden switch until the display 
reads SET READY.
2.  To adjust the ready temperature, press the (-) 
button to decrease, or (+) to increase the ready 
temperature.
3.  When finished, press and release DONE to save 
the new setting, exit the SET READY function and 
advance to the next function screen, REFILL. 
Another alternative is to press and release either 
ON/OFF switch located on the front switch panel 
to exit the SET READY function and return to the 
MAIN SCREEN.
REFILL - Range: 20 to 230
  This function allows the operator to adjust the 
sensitivity of the refill circuit. This is mainly a trouble-
shooting feature. Water in different geographical loca-
tions can have different conductivities. By adjusting 
the sensitivity of the refill circuit, this will allow the 
brewer to operate under various water conditions.
XXX REFILL -> XXX
 (-)  DONE  (+)
41343 080108