Bunn 41343 Manuel D’Utilisation

Page de 40
Page 30
ENABLE ADS?
 
This function allows the operator to choose whether 
or not to display the advertising message that was en-
tered into the brewer with an AD CARD. This message 
will be displayed when the brewer is not in use.
Procedure to Enable/Disable Ads:
1.  Press and hold upper right hidden switch until the 
display reads UNITS. Release switch. Continue to 
press and release switch until the display reads 
ENABLE ADS. The YES or NO will be flashing to 
indicate the current selection.
2.  Press and release the NO to disable this function 
(no ads will be displayed on the screen), or;
3.  Press and release the YES to enable this function 
(ads will be displayed on screen).  
4.  When finished, press and release DONE to save 
the new setting, exit the ENABLE ADS function and 
advance to the next function screen, SET  TEMP.  
Another alternative is to press and release the 
ON/OFF switch (either on DUAL brewers) located 
on the front switch panel to exit the ENABLE ADS 
function and return to the MAIN SCREEN.
SET TEMP  - Range: 185˚F (85˚C) to 205˚F (96˚C)
 
This function allows the operator to set the brew 
water temperature in the tank.  It also sets the hot 
water faucet dispense temperature.
PROGRAMMING FUNCTIONS - (cont.)
Procedure to set brew temperature:
1.  Press and hold upper right hidden switch until the 
display reads UNITS. Release switch.  Continue to 
press and release switch until the display reads  
SET TEMP.
2.  To adjust the brew temperature, press (-) to de-
crease or (+) to increase the brew temperature.
3.  When finished, press and release DONE to save 
the new setting, exit the SET TEMP function and 
advance to the next function screen,  SET READY. 
Another alternative is to press and release  the ON/
OFF switch (either on DUAL brewers) located on 
the front switch panel to exit the SET TEMP func-
tion and return to the MAIN SCREEN.
SET READY - Range: 185˚F (85˚C) to 203˚F (95˚C)
 
This function allows the operator to set the mini-
mum temperature allowable to start a brew cycle. The 
range can be from 185˚F (85˚C) to within 2˚F (-1.7°C) 
of the SET TEMP. The water must be at the SET READY 
temperature or higher for the display to indicate READY 
TO BREW. If brew lockout is enabled, the brewing pro-
cess will not start below this READY temperature.
NOTE: The upper limit for SET READY temperature 
is 2˚F (-1.7°C) less than the water temperature (SET 
TEMP) setting.
-1000
213.8
101.0
200
93.3
-500
212.9
100.5
200
93.3
0
212.0
100.0
200
93.3
500
211.1
99.5
200
93.3
1000
210.2
99.0
200
93.3
1500
209.3
98.5
200
93.3
2000
208.4
98.0
200
93.3
2500
207.4
97.4
200
93.3
3000
206.5
96.9
199
92.8
3500
205.6
96.4
198
92.2
4000
204.7
95.9
197
91.7
4500
203.8
95.4
196
91.1
5000
202.9
94.9
195
90.6
5500
201.9
94.4
195
90.6
6000
201.0
93.9
194
90.0
6500
200.1
93.4
193
89.4
7000
199.2
92.9
192
88.9
7500
198.3
92.4
191
88.3
8000
197.4
91.9
190
87.8
8500
196.5
91.4
189
87.2
9000
195.5
90.8
188
86.7
9500
194.6
90.3
187
86.1
10000
193.7
89.8
186
85.6
Brew water temperature is factory set at 200
∞ F (93.3∞ C)
Areas of high altitude will require lowering this tempera-
ture to prevent boiling.  This chart should be used as a
guide when readjusting the brew water temperature.
Altitude
(Feet)
Boiling point
of water
∞ F          ∞ C
Recommended
water temperature
∞ F          ∞ C
NOTICE
35665.0000A  05/04  © 2004  Bunn-O-Matic Corporation
ENABLE ADS ?
 NO DONE  YES
SET TEMP: XXX°
 (-)  DONE  (+)
SET READY: XXX°
 (-)  DONE  (+)
41343 080108