Aga Ranges EINS513307 Manuel D’Utilisation

Page de 18
AGA ELECTRIC RANGE (EC LM - 2 OVEN & EE LM - 4 OVEN) - OWNERS MANUAL
Installation Section
Remember, when replacing a part on this appliance, use only spare parts that you can be assured conform to 
the safety and performance specification that we require. Do not use reconditioned or copy parts that have not 
been clearly authorised by AGA-RANGES.
CAUTION: THIS UNIT IS HEAVY, PROPER EQUIPMENT AND ADEQUATE MANPOWER MUST BE USED IN 
MOVING THE RANGE TO AVOID DAMAGE TO THE UNIT OR THE FLOOR
GENERAL NOTES
NOTE: THESE INSTALLATION INSTRUCTIONS SHOULD BE LEFT WITH THE APPLIANCE AND THE USER 
TO RETAIN FOR FUTURE REFERENCE.
The Aga range is delivered unassembled. Before installation can be made, the site is inspected for suitability by 
an authorised Aga distributor and corrected where necessary to conform with local installation codes or in the 
absence of local codes with:
NATIONAL ELECTRICAL CODES ANSI/NFPA70
Assembly is undertaken on site by the same Aga distributor to ensure correct performance and safety.
INSTALLATION
THE INSTALLATION OF THIS APPLIANCE MUST NOT BE LESS THAN 12mm FROM ANY SURFACE.
With specific exceptions, the installing of any type of Aga Range is subject to the respective directions contained 
in current issue of the local Building Regulations. In addition, planning permission may need to be obtained, 
which should be applied for separately.
The complete range is floor-mounted and the space in which the appliance is to be fitted must have the following 
minimum dimensions:-
A minimum clearance of 60mm is required above the raised insulating cover handle.
Side clearance zero unless range is fitted against a wall, where 116mm is required at the right hand side for oven 
access.
In addition a minimum clearance of 1000mm must be available at the front of the cooker to enable the cooker to 
be serviced.
To eliminate the risk of burns or fire by reaching over heated surface units, cabinet storage space located above 
the surface units should be avoided. If cabinet storage is to be provided, the risk can be reduced by installing a 
range hood that projects horizontally, a minimum of 5" beyond the bottom of the cabinets.
NOTE: AGA RANGES ARE DELIVERED EX-WORKS UNASSEMBLED. ASSEMBLY IS UNDERTAKEN BY 
file:///D:/System/DATA/Dx/ds1/Us/iss1/EINS513307/EINS513307.htm (3 of 18)8/16/2006 9:18:22 AM