GE ZGU3650 Guide De Spécification

Page de 4
For answers to your Monogram,
®
GE Profile Performance Series,
GE Profile
or GE appliance questions, call 
GE Answer Center
®
service, 800.626.2000.
Monogram.
Specification Created 7/00
Dimensions and Clearances (in inches)
Advance Planning
19-3/4"
36"
3"
18-1/8"
4-5/8" Min. 
to Vertical 
Combustible
Surface
2-1/4"
Min.
34-1/2"
8-13/16" Min.
to Wall
13"
Max.
36" Min.
3-7/8" Min.
to Vertical
Combustible
Surface When 
Installed
8" Min. to Wall 
When Installed 
Both Sides 
1-1/2" Min. to Front of 
Countertop When Installed
18" 
Min.
30" 
Min.
• Refer to “Installation Preparation”, found in 
installation instructions packed with product, 
for information on appropriate placement and 
necessary clearances when planning installation.
• Avoid placing cabinetry directly above cooktop 
when possible.
• If cabinetry is used above the cooking surface:
–Use cabinets no more than 13” deep.
–Maintain 30” minimum clearance between 
the cooktop and unprotected cabinets directly 
above the cooktop.
–If clearance is less than 30”, protect cabinet 
bottoms with flame-retardant millboard at least 
1/4” thick, or gypsum board at least 3/16” thick, 
covered with 28 gauge sheet steel or .02”
thick copper.
–Clearance between cooktop and protected 
cabinetry must not be less than 24”.
–An exhaust hood that projects at least 5”
beyond front of cabinets can reduce risk of 
burns caused by reaching over heated 
surface units.
–Working areas adjacent to the cooktop should 
have 18” minimum clearance between cooktop 
and cabinet bottom.
• Use the Monogram gas updraft cooktop with any 
36” or wider exhaust hood, if desired; no special 
ventilation is required.
• Installation must conform with local codes. In the 
absence of local codes, the gas cooktop must 
comply with the National Fuel Gas Code, 
ANSI Z223.1, latest edition.
ZGU3650—GE Monogram 36” Updraft Cooktop with 5 Burners