10 
P
ARAGON 
II
 
U
SER 
G
UIDE 
 
 
 
3.  Test Channel UKVM (CIM UKVM): Used by administrator to check if CIM is functioning 
properly. Press the Ç or È button to change channel number. Display will read “OK”, 
“None”, or “Failed.”  Press ESC to return to normal display.   
If a “failed” condition is detected, make sure Category 5e UTP cable is installed properly and 
secured, or try using another CIM (UKVM) to see if CIM under test has become defective. 
 
Test Chan.  UKVM 
UKVM:  60   OK 
 
Figure 14 Channel CIM  (UKVM) Test 
4.  Test Stack Unit:  Press the Ç or È button to select the corresponding Stacking Unit ID for 
any connected units.  If there are no Stacking Units connected, the LCD will display “None”.  
If there are Stacking Units connected, the LCD should read “OK” for each unit.  Press ESC 
to return to normal display. 
 
5.  Stacking Support: Press the Ç or È button to set the Stacking Unit ID number  (0 – 3 for a 
P2-UMT832M or “0” or “1” for a P2-UMT1664M).  The default is set to “0” (no Stacking 
Units connected).  If you wish to add Stacking Units, this number must be equal to the 
number of Stacking Units connected.  Press ESC to return to normal display. 
 
Stacking Support 
Unit(s):  0-3 
Figure 15 Stacking Support 
6.  Set LCD Contrast: Modifies contrast level of front panel LCD Display. Press the Ç or È 
button to increase or decrease contrast, and press the ESC button to return to normal display. 
 
Set LCD Contrast 
Use Up/Down Keys  
Figure 16 Set LCD Contrast 
Note: LCD contrast can also be adjusted by holding the 
Å
 button and pressing the 
Ç
 or 
È
 
button at any time. 
7.  Re-Configure: Paragon II will automatically configure the system as computers or devices 
are added or removed. However, the system administrator can use this function to scan and 
re-configure the system manually. When complete, it will return to normal display. 
 
Re-Configure 
Searching Now… 
 
Figure 17 Auto Configure 
8.  Set IP Address: As administrator, you may change Paragon II’s IP address directly from the 
front panel of the device.  The Paragon II’s current IP address will be displayed, along with a 
cursor. Use the Å and Æ keys to move the cursor over digit-by-digit, and use the Ç or È 
arrow keys to change the value of that digit.  Press the ENT button when the new IP address 
has been set.  Press the ENT button again to save changes and reboot the unit when asked to 
“Save Changes?” The unit will restart with the new network address.