2. Remove the hold-down screw and terminal block cover.
A. Neutral ground wire 
B. External ground conductor screw
C. Center, silver-colored terminal block screw
D. Terminal block cover and hold-down screw
A
B
C
D
3. Install strain relief.
Style 1: Power supply cord strain relief
Remove the screws from a 
3
/
4
" (19 mm) UL listed strain relief 
(UL marking on strain relief). Put the tabs of the two clamp 
sections into the hole below the terminal block opening so 
that one tab is pointing up and the other is pointing down, 
and hold in place. Tighten strain relief screws enough to hold 
the two clamp sections together.   
A. Strain relief tab pointing up
B. Hole below terminal block opening
C. Clamp section
D. Strain relief tab pointing down
A
B
C
D
Put power supply cord through the strain relief. Be sure that 
the wire insulation on the power supply cord is inside the 
strain relief. The strain relief should have a tight fit with the 
dryer cabinet and be in a horizontal position. 
 
Do not further tighten strain relief screws at this point. 
Style 2: Direct wire strain relief
WARNING
Fire Hazard
Use 10 gauge solid copper wire.
Use a UL listed strain relief. 
Disconnect power before making electrical connections.
Connect neutral wire (white or center wire) to center 
terminal (silver). 
Ground wire (green or bare wire) must be connected to 
green ground connector. 
Connect remaining 2 supply wires to remaining 
2 terminals (gold). 
Securely tighten all electrical connections. 
Failure to do so can result in death, fire, or 
electrical shock.
Unscrew the removable conduit connector and any screws 
from a 
3
/
4
" (19 mm) UL listed strain relief (UL marking on 
strain relief). Put the threaded section of the strain relief 
through the hole below the terminal block opening. 
Reaching inside the terminal block opening, screw the 
removable conduit connector onto the strain relief threads.   
A
B
C
A. Removable conduit connector
B. Hole below terminal block opening
C. Strain relief threads