THERMAL FUSES
FIG. 17 THERMAL FUSES
P1415
Location:
The thermal fuses are located inside the rear of the
hood connected to the left and right rear tank heater
terminals.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the thermal fuse from the right tank
heater terminal and tank heater terminal block or
the thermal fuse from the left tank heater terminal
and the tank heater terminal block.
3. With an ohmmeter, check for continuity across the
thermal fuse terminals.
If continuity is present as described, the thermal fuse
is operating properly.
If continuity is not present as described, replace the
thermal fuse.
FIG. 18 THERMAL FUSE TERMINALS
P1421
SERVICE (cont.
Removal and Replacement:
1. Disconnect the thermal fuse from the right tank
heater terminal tank heater terminal block or the
thermal fuse from the left tank heater terminal and
the tank heater terminal block.
2. Remove thermal fuse and discard.
3. Connect  new  thermal  fuse  to  right  tank  heater
terminal  tank  heater  terminal  block  or  the  left
thermal fuse to the left tank heater terminal and the
tank heater terminal block.
4. Refer to Fig. 18 when reconnecting thermal fuses.
28182 090100
Right Thermal Fuse to Tank
Heater Terminal Block
Left Thermal Fuse to Tank
Heater Terminal Block