Bunn CWTF-APS-MV Instruction De Maintenance

Page de 31
Page 27
SERVICE (cont.)
DIGITAL TIMER (Late Models)
FIG. 21 DIGITAL TIMER
P1415.40
LATE MODELS
28182 090100
Location:
The timer is located inside the front of the trunk on
the upper right side of the component bracket.
Test Procedure.
NOTE: Do not remove or install wires while timer board
is installed. Pressure applied to one side may cause
damage to the board.
1. Disconnect the brewer from the power source and
remove the front access panel.
2. Remove  the  two  #8-32  screws  securing  circuit
board to the mounting bracket.
3. Remove circuit board and spacers (as required).
4. With a voltmeter, check the voltage across termi-
nals TL1 and TL2 when the "ON/OFF" switch is in
the "ON" (upper) position. Connect the brewer to
the power source. The indication must be:
a) 120 volts ac for two wire 120 volt models
b) 120 volts ac for three wire 120/208 volt and
120/240 volt models.
5. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #6.
If  voltage  is  not  present  as  described,  refer  to  the
Wiring  Diagrams  and  check  the  brewer  wiring  har-
ness.
6. With a voltmeter, check the voltage across termi-
nals TL1 and TL4 when the "ON/OFF" switch is in
the "ON" (upper) position. Connect the brewer to
the power source. The indication must be 0 volts.
If voltage is as described, proceed to #7.
If voltage is not as described, disconnect the brewer
from the power source and replace the timer.
7. With a voltmeter, check the voltage across termi-
nals TL1 and TL4 when the "ON/OFF" switch is in
the "ON" position. Connect the brewer to the power
source and press the "START" switch. The indica-
tion must be as follows:
a) 120 volts ac for two wire 120 volt models.
b) 120 volts ac for three wire 120/208 volt and 120/
240 volt models.
If voltage is present as described, the brew timer is
operating  properly.  Reset  the  timer  as  required,  to
obtain the desired brew volume.
If voltage is not present as described, disconnect the
brewer from the power source and replace the timer.
Removal and Replacement:
1. Remove  the  two  #8-32  screws  securing  circuit
board to the mounting bracket.
2. Remove circuit board and spacers (as required).
3. Remove all wires from the timer.
4. Attach  all  wires  to  the  replacement  timer  board
prior to installation to the component mounting
bracket.  Refer to FIG. 22 when reconnecting the
wires.
5. Install  new  circuit  board  with  spacers  (as  re-
quired) to the component mounting bracket.
6. Adjust the timer as described below.
Timer Setting:
NOTE: Prior to setting or modifying volumes, check
that the brewer is connected to water supply, the tank
is properly filled, and a funnel and server are in place.
NOTE:  All  volume  settings  must  be  done  with  the
sprayhead installed.
1. Modifying brew volumes. To modify a brew vol-
ume, first check that the SET/LOCK switch is in the
“SET” position on the circuit board.