LG DLEX3875V Manuel Du Propriétaire

Page de 148
Your  dryer  features  FlowSense
TM
,  an  innovative 
sensing system that automatically detects blockages 
and restrictions in dryer ductwork. Keeping ductwork 
clean of lint buildup and free of restrictions allows 
clothes to dry faster and reduces energy use.
NOTE:  When  the  dryer  is  first  installed,  this  test 
should  be  performed  to  alert  you  to  any  existing 
problems  with  the  exhaust  duct  in  your  home.  
However, since the test performed during normal 
operation  provides  more  accurate  information  on 
the  condition  of  the  exhaust  duct  than  does  the 
installation test, the number of bars displayed during 
the two tests may not be the same.
To activate the duct condition test :
NOTE: Dryer heating test must be performed before 
proceeding. Then perform the duct condition test 
below:
Press and hold the DAMP DRY BEEP and 
TEMP.CONTROL buttons at the same time. 
While holding these buttons, press POWER 
ON/OFF. 
The display will show the FLOW CHECK start 
screen.
DUCT CONDITION TEST
Correct Venting
Restricted or Blocked Airflow
Avoid long runs or runs with multiple elbows 
or bends.
Check for blockages and lint buildup.
Make sure the ductwork is not crushed  
or restricted.
1
2
If no bars are shown in 
the display, the ductwork 
is free from blockages  
or restrictions. 
If all bars are lit, the 
dryer ductwork has a 
blockage that needs to 
be removed immediately. 
IMPORTANT: Do NOT interrupt the test cycle!
NOTE : Even if no bars are displayed during the 
duct condition test, some restrictions may still be 
present in the exhaust dust. Refer to pages 14-15 
for more information. 
THE DUCTWORK IS FREE 
FROM BLOCKAGES OR 
RESTRICTIONS.
COMPLETED FLOW CHECK
THE DUCTWORK HAS 
A BLOCKAGE THAT NEEDS
TO BE REMOVED
IMMEDIATELY.
NEED FLOW CHECK
3
Press START/PAUSE. The 
dryer will run for 
approximately 2 
minutes to test 
for blockages or 
restrictions to air 
flow in the ductwork. 
FLOW CHECK
0:02
EST. TIME
REMAINING
HIGH
26