RAD Data comm ASM-60 Manuel D’Utilisation

Page de 90
ASM-60 Installation and Operation Manual 
Chapter 4  Management from a Terminal 
 
Starting the Control Session 
4-3 
Terminal Management Menus 
shows a map of the management menus in the ASM-60 embedded 
software. The second level menus (Configuration, Display, Reset) are described in 
its own section in this chapter. The Alarms, Log File, VDSL Performance and Test 
menus are described in 
Chapter 5
4. Reset
5. Debug
3. Test
1. Start LEDs Test
1. Factory Setting
2. Reset Device
3. Reset Device
4. Reset FPGA
1. Configuration
1. Data Rate
1. 4096 kbps
2. 6144 kbps
3. 10240 kbps
2. Display
1. Status
   
4. VDSL Performance
3. Log File
2. Alarms
    
Main Menu
 
Figure 4-1.  ASM-60 Management Software  
 
The Debug option is reserved for the use only by the authorized personnel. 
 
4.3  Starting the Control Session 
Once you have installed the ASM-60 modems at the central and remote locations, 
and completed the installation and operation procedures described in 
, you can start the control session. 
When the communication link between the modems is established, the ASM-60 
software identifies the unit type (ASM-60/CO or ASM-60/CPE), and runs the 
start-up self-test. 
During the initialization, the following message is displayed: 
Initializing ASM-60/CO or Initializing ASM-60/CPE 
If errors were detected during the self-test, ASM-
60 displays the following message: 
Initialization Failed 
If the self-test is successful, ASM-60 displays the Main menu (see 
Note