Mnemonic
Command
number
number
Meaning
ROL
2
Rotate left
ROR
1
Rotate right
MVP
4
Move to position
MST
3
Motor stop
RFS
13
Reference search
SCO
30
Store coordinate
CCO
32
Capture coordinate
GCO
31
Get coordinate
2.4.2 Parameter commands
These commands are used to set, read and store axis parameters or global parameters. Axis parameters can be set
independently for every axis, whereas global parameters control the behaviour of the module itself. These
commands can also be used in direct mode and in stand-alone mode.
independently for every axis, whereas global parameters control the behaviour of the module itself. These
commands can also be used in direct mode and in stand-alone mode.
Mnemonic
Command
number
number
Meaning
SAP
5
Set axis parameter
GAP
6
Get axis parameter
STAP
7
Store axis parameter into EEPROM
RSAP
8
Restore axis parameter from EEPROM
SGP
9
Set global parameter
GGP
10
Get global parameter
STGP
11
Store global parameter into EEPROM
RSGP
12
Restore global parameter from EEPROM
2.4.3 I/O port commands
These commands control the external I/O ports and can be used in direct mode and in stand-alone mode.
Mnemonic
Command
number
number
Meaning
SIO
14
Set output
GIO
15
Get input
SAC
29
Access to external SPI device
2.4.4 Control commands
These commands are used to control the program flow (loops, conditions, jumps etc.). It does not make sense to
use them in direct mode. They are intended for stand-alone mode only.
use them in direct mode. They are intended for stand-alone mode only.
Mnemonic
Command
number
number
Meaning
JA
22
Jump always
JC
21
Jump conditional
COMP
20
Compare accumulator with constant
value
value
CLE
36
Clear error flags
CSUB
23
Call subroutine
RSUB
24
Return from subroutine
WAIT
27
Wait for a specified event
STOP