Whirlpool W10029770A Manuel D’Utilisation

Page de 28
9
Install Range Hood
1. Using 2 or more people, hang range hood on 2 mounting 
hooks through the rectangular cutouts on back of hood.
2. Level the hood with leveling screws in mounting hooks or 
rectangular cutouts, using a level across bottom of hood.
3. Secure hood with 4 screws through remaining 4 holes in 
hood.
4. Install transition with 2 screws.
Connect Vent System
(for vented installations only)
1. Fit vent system over transition piece.
2. Seal connection with clamps.
Make Electrical Connection
1. Disconnect power.
2. Remove terminal box cover.
3. Remove the knockout in the terminal box cover and install the 
UL-listed or CSA approved
 ¹⁄₂" strain relief.
4. Run 3 wires, black, white and green (14AWG) in 
¹⁄₂" conduit 
from service panel to terminal box. 
5. Use UL listed wire connectors and connect black wires 
together.
6. Use UL listed wire connectors and connect white wires 
together.
7. Connect ground wire to green and yellow ground wire in 
terminal box using UL listed wire connectors.
A. Mounting hooks
B. Mounting screws
C. Leveling screws
D. Centerline on wall
E. Transition
F. 3.5 x 9.5 mm screws
G. Terminal box
A. Vent system
B. Transition piece
WARNING
Excessive Weight Hazard
Use two or more people to move and install 
range hood.
Failure to do so can result in back or other injury.
A
B
C
D
E
B
F
F
G
A
B
A. UL-listed or CSA 
approved strain relief
B.
¹⁄₂" conduit
C. Terminal box
D. Black wires
E. Green (or bare) wire connected 
to yellow-green wire
F. White wires
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
D
C
B
E
F
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire 
in terminal box.
Failure to do so can result in death or electrical shock.