Maxon Telecom MODMAX MM-6280IND Manuel D’Utilisation

Page de 70
 
 
Extended AT Commands Manual 
Page 30 of 70 
2009-06-25 
7 .   D A T A   C A L L   S E T - U P  
The following tables describe MO data call procedures. 
Call released or failed (Uses DTR pin) 
Table 7.51 Notification command 
Notify 
TE2 
Å
 
MT2 
NO CARRIER 
7.1.  Data Calls 
SIM Card with Data Number enabled (Contact Telstra and ask to activate 
Code 2620 on the SIM account) 
7.1.1.1. 
MO data call 
Table 7.52 
Command  TE2  Æ  MT2   
Command  TE2 
Æ
  MT2 ATD<phone_number> 
Notify 
TE2 
Å
  MT2 
CONNECT (Data call connected) 
Connect <Speed> if connect_baud is set. 
NO CARRIER (Data call failure) 
Value 
phone_number: 
for Packet Switched Data: *99# (Australia – requires authentication) 
This requires setting up an APN (Please refer to MM-6280IND-HSDPA AT 
Commands manual) 
for Circuit Switched Data: You will need a data number ( Code 2620 activated 
on the SIM account) 
 
7.1.1.2. 
MT Data Call 
Notify 
TE2  Å  MT2 
AT: RING 
Buzzer: Audible (excepting where $$RCV_MODE is 1) 
CRT LED: ON for duration of ring and when MT data 
call in progress. CRT LED should be off otherwise 
Command  TE2 
Æ
  MT2 
ATA (answer data call) 
Notify 
TE2 
Å
  MT2 
CONNECT (Data call connected) 
CONNECT <SPEED> if connect_baud is enabled. 
NO CARRIER (Data call failure) 
Call State 
Command  TE2 
Æ
  MT2 
+++ (escape command to go to off-line command state) 
ATH (release call) 
Notify 
TE2 
Å
  MT2 NO 
CARRIER