VAX RS 232C Manuel D’Utilisation

Page de 24
Page 18 of 24 
5.9. Filter Settings 
 
Perform Filter (HPF/LPF) settings of Input / Output channels. 9000Series Amplifier 
responds with the same data as that received.   
 
Note: Command cannot be received during power off. 
 
A2H, 04H, <Channel Attribute>, <Channel Number>, <HPF/LPF>, <Value> 
 
<Channel Attribute>   
00H: Input channel   
01H: Output channel   
 
<Channel Number>   
00H - 07H (Input channel 1 - 8)   
00H - 07H (Output channel 1 - 8)   
 
<HPF/LPF> 
00H: High Pass Filter 
    01H: Low Pass Filter 
 
<Frequency Value> 
HIGH PASS FILTER   
TABLE – 00H 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
LOW PASS FILTER   
TABLE – 01H 
 
   
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Example: Setting the Input Channel 3’s High Pass Filter to 31.5 Hz. 
A2H, 04H, 00H, 02H, 00H, 03H 
Value 
HEX 
DEC 
HPF (Hz) 
00H 0  OFF 
01H 1 
20 
02H 2 
25 
03H 3  31.5 
04H 4 
40 
05H 5 
50 
06H 6 
63 
07H 7 
80 
08H 8 
100 
09H 9 
125 
0AH 10 
160 
0BH 11 
200 
0CH 12 
250 
0DH 13 
315 
0EH 14 
400 
Value 
HEX 
DEC 
LPF (Hz) 
00H 0 
4k 
01H 1 
5k 
02H 2  6.3k 
03H 3 
8k 
04H 4 
10k 
05H 5  12.5k 
06H 6 
16k 
07H 7 
20k 
08H 8  OFF