VAX RS 232C Manuel D’Utilisation

Page de 24
Page 19 of 24 
5.10. Input Sensitivity Setting 
 
Performs input sensitivity setting of Input channel. 9000Series Amplifier responds with the 
same data as that received.  Input sensitivity setting is enabled only for the channel on 
which the D-001T or AN-001T is used.   
 
Note: Command cannot be received during power off. 
 
ACH, 02H, <Channel Number>, <Value> 
 
<Channel Number>   
00H - 07H (Input channel 1 - 8)   
 
<Value > 
INPUT SENSITIVITY TABLE 
 
Value 
Value 
HEX 
DEC 
Sense 
(dB) 
HEX 
DEC 
Sense 
(dB) 
00H 
0 -10 
05H 
5 -42 
01H 
1 -18 
06H 
6 -48 
02H 
2 -24 
07H 
7 -54 
03H 
3 -30 
08H 
8 -60 
04H 4 
-36 
 
 
   
Example: Setting the input sensitivity of Input Channel 5 to –24 dB.       
ACH, 02H, 04H, 02H 
 
5.11. Phantom Power ON/OFF Setting 
 
Sets the phantom power of Input channel to ON or OFF. 9000Series Amplifier responds 
with the same data as that received. 
 
Note: Command cannot be received during power off. 
 
87H, 02H, <Channel Number>, <OFF/ON> 
 
<Channel Number> 
00H - 07H (Input channel 1 - 8)   
 
<OFF/ON> 
        00H: PHANTOM OFF 
        01H: PHANTOM ON 
 
Example: Setting the phantom power of Input Channel 1 to ON. 
87H, 02H, 00H, 01H