Whirlpool CGT8000XQ Manuel De Montage

Page de 116
27
ELECTRIC DRYER ELECTRICAL CONNECTIONS
3.  Connect remaining wires to outer terminal block.
4.  Connect a separate copper ground wire from the external 
ground conductor to an adequate ground.
Use for direct wire or power supply cord where local codes 
do not permit connecting cabinet-ground conductor to 
neutral wire.
Connecting Neutral Wire
1.  Remove center terminal block screw. Also remove neutral 
ground wire by removing external ground conductor screw.
2.  Connect neutral wire and neutral wire of power supply cord/
cable to center terminal block.
Connecting 3-Wire Connection: Optional
1.  Remove cardboard from beneath washer/dryer. Place a level 
on top edges of washer/dryer, checking each side and front. 
If not level, tip washer/dryer and adjust feet up or down as 
shown in Steps 3 and 4, repeating as necessary.
Leveling Stacked Washer/Dryer
LEVELING
Leveling your washer/dryer properly reduces excess noise and 
vibration.
Not Level
LEVEL
Not Level