Ventilation appliances
A R 400 131
Metal housing
Max. air output 950 m³/h
Inside installation
Air extraction
Max. air output 950 m³/h
Inside installation
Air extraction
A R 400 140
Metal housing
Max. air output 1,210 m³/h
Inside installation
Air extraction
Max. air output 1,210 m³/h
Inside installation
Air extraction
Installation accessories
A A 009 910
A A 009 910
Ceiling installation set
A D 702 042
Pipe adapter from DN 200 circular to
DN 150/125 circular
Fitting to DN 150 or 125 by cutting off
the diameters not needed.
DN 150/125 circular
Fitting to DN 150 or 125 by cutting off
the diameters not needed.
Special accessories
A A 009 910
A A 009 910
Ceiling installation set
Installation accessories for the air
recirculation ducts you will find at the
pages 236–239 .
recirculation ducts you will find at the
pages 236–239 .
Remote fan unit
A R 400
– AR 400 140 for maximum output for
downdraft ventilation and motorless
hoods
hoods
– Installation in a separate room
allows lower noise level in the
kitchen
kitchen
– To be combined with motorless
hoods, downdrafts or ceiling
ventilation
ventilation
Output
Performance output level 3/4:
Air output according to DIN EN 61591.
Sound power and sound pressure
depending on built-in situation.
Air output according to DIN EN 61591.
Sound power and sound pressure
depending on built-in situation.
AR 400 131, NW 150
700 / 950 m³/h.
AR 400 140, NW 200
930 / 1,210 m³/h.
For the characteristics of each output
level with/without intensive mode
please refer to the table with the
respective motorless ventilation
products.
700 / 950 m³/h.
AR 400 140, NW 200
930 / 1,210 m³/h.
For the characteristics of each output
level with/without intensive mode
please refer to the table with the
respective motorless ventilation
products.
Features
Metal housing, zinc-plated.
Pipe connections air intake: 1 x DN 200
cylindrical, 4 x DN 150 cylindrical.
Pipe connection pressure side:
AR 400 131: DN 200 and 150
AR 400 140: DN 200
Spare cover for closing air intake.
Pipe connections air intake: 1 x DN 200
cylindrical, 4 x DN 150 cylindrical.
Pipe connection pressure side:
AR 400 131: DN 200 and 150
AR 400 140: DN 200
Spare cover for closing air intake.
Planning notes
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood's power
supply line needs a suitable safety
switch.
Installation in the drawer area with
double height or on the floor with
cut-out in the furniture base. Air intake
with flat duct max. 2x DN 150 behind
the drawers requires worktop depth of
min. 700 mm. Cabinets without plinth
possible.
Please refer to page 230–233 for
recommended configurations of
downdraft ventilations and remote fan
units and the needed ducting
elements.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
For noise optimisation, use the silencer
SD 011 050.
For details of the remote fan unit's
effective air output in combination with
a hood or downdraft, refer to the table
section.
air extraction mode and a chimney-
vented fireplace, the hood's power
supply line needs a suitable safety
switch.
Installation in the drawer area with
double height or on the floor with
cut-out in the furniture base. Air intake
with flat duct max. 2x DN 150 behind
the drawers requires worktop depth of
min. 700 mm. Cabinets without plinth
possible.
Please refer to page 230–233 for
recommended configurations of
downdraft ventilations and remote fan
units and the needed ducting
elements.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
For noise optimisation, use the silencer
SD 011 050.
For details of the remote fan unit's
effective air output in combination with
a hood or downdraft, refer to the table
section.
Connection
Fan output 355/520 W .
Connecting cable 1.05 m.
Extension cable 5 m.
Connecting cable 1.05 m.
Extension cable 5 m.