Elica EAR134S2 Manuel De Montage

Page de 32
5
List of Materials
Parts supplied
CAUTION!
Remove carton carefully, wear gloves to protect against
sharp edges.
WARNING!
Remove the protective film covering the product before
putting into operation.
Metal grease filters:  
 
- Model EAR628SS: 2 filters 
 
- Model EAR134SS: 2 filters 
 
- Model EAR140SS: 3 filters 
 
- Model EAR146SS: 4 filters
1 - 10” (25.4 cm) square to 10” (25.4 cm) round 
 
duct transition with damper.
2 - 1½” x 22” stainless steel hood spacer
4 - 5 x 45 mm mounting screws for cabinet
10 - 4.2 x 8 mm mounting screws
2 - 18mm spacer screw (only on model EAR628SS) 
 
Parts not supplied
Optional Accessories
Home power supply cable
1 - ½” (1.3 cm) UL listed or CSA approved strain relief
3 - UL listed wire connectors
1 wall or roof cap
Metal vent system
Tools/Materials required
Level
Drill
1¼” (3 cm) drill bit
⅛” (3 mm) drill bit
Pencil
Wire stripper or knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking 
 
compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
 Location Requirements
IMPORTANT: Observe all governing codes and ordinances. 
Have a qualified technician install the hood insert. It is the 
installer’s responsibility to comply with installation clearances 
specified on the model/serial rating plate. The model/serial 
rating plate is located on the rear wall’s right side of the hood 
insert.
The hood insert location should be away from strong draft 
areas, such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. 
Given dimensions provide minimum clearance.
The hood insert must be surrounded by a custom built enclo-
sure with hood cabinet capable of supporting 75 lb (34 kg).
Grounded electrical outlet is required. See “Electrical
Requirements” section on page 4.
All openings in ceiling and wall where canopy hood will be 
installed must be sealed.
For Mobile Home Installations
The installation of this hood insert must conform to the Manu-
factured Home Construction Safety Standards, Title 24 CFR, 
Part 328 (formerly the Federal Standard for Mobile Home 
Construction and Safety, Title 24, HUD, Part 280) or when 
such standard is not applicable, the standard for Manufac-
tured Home Installation 1982 (Manufactured Home Sites, 
Communities and Setups) ANSI A225.1/NFPA 501A, or latest 
edition, or with local codes.
 
 
Dimensions and Clearances
This range hood has the flexibility to be installed in two differ-
ent ways, depending on the width measurement or working 
area between the left and right cabinetry.   Before beginning, 
it is important to determine the dimension of this working 
area and to consider the measurements detailed in the table 
below.
Range 
Hood 
Models
Range Width  
without spacers
Range Width  
with spacers
EAR628SS
28½” (72 cm)
30” (76.2 cm)
EAR134SS
34½” (87 cm)
36” (91.44 cm)
EAR140SS
40½” (102 cm)
42” (106.68 cm)
EAR146SS
46½” (117.5 cm)
48” (121.92 cm)
 
 
 
 
 
 
 
 
IMPORTANT:
Minimum distance “X”: 24” (61 cm) from electric cooking surfaces.
Minimum distance “X”: 30” (76.2 cm) from gas cooking surfaces.
Suggested maximum distance “X”: 36” (91.4 cm).
“X” bottom of canopy to
cooking surface
Hood insert cabinet must be
capable of supporting
75 lb (34 kg)
22” 
(55.9 cm)
Hood insert
depth
See the above table