Venting Methods
The hood exhaust opening has a 10” diameter round vent  
 
outlet. 
On installations using the 600 CFM Blower Motor 
 
Systems, 8” round vent system is  recommended. 
On installations using the 1200 CFM Blower Motor 
 
Systems, a 10” round vent system should be used. 
You can use a smaller round vent system , but there will  
 
be a  louder sound level. 
 
NOTE: Flexible vent is not recommended.  Flexible vent  
 
creates back pressure and air turbulence that greatly 
 
reduce performance. Vent system can terminate either  
 
through the roof or wall. To vent through the wall, a 90° 
 
elbow is needed.
Prepare the Location
 
Disconnect power.
Determine which venting method to use: roof or wall  
 
exhaust.
Select a flat surface for assembling the hood insert. 
 
Place covering over that surface.
It is recommended that the vent system be  installed  
  before hood is installed.
Before making cutouts, make sure there is proper  
  clearance within the ceiling or wall for exhaust vent.
Hood insert should be installed a minimum 24” (61 cm)  
  above an electric cooktop surface and 30” (76.2 cm)  
  above a gas cook top surface.  The maximum  
  recommended height over both cook tops is 36” (91.44  
  cm).
Check that all installation parts have been removed  
  from the shipping carton.
Using 2 or more people, lift hood insert onto covered  
 
surface.
Remove the filters. See the “Cleaning” section. 
 
Stainless Steel Hood Spacer Installation
You can elongate 1.5” of your range hood width (¾” per side), 
installing the stainless steel spacers included with your range 
hood. 
Unpack the spacer and take off the protective.
Put each one on the right and the left side
Fasten hood spacer using four 5 x 45 mm screws to the  
 
hood cabinet and tighten securely. 
1.
2.
3.
4.
5.
1.
2.
3.
A
B
B
A
Roof venting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
A. 10” (25.4 cm) round vent
B. Roof cap
 
Wall Venting 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
A. 10” (25.4 cm) round vent
B.Wall cap
Install Range Hood into  
Hood Cabinet
 
The range hood attaches to the hood cabinet using four 
mounting screws and washers.
NOTE: Hood cabinet must be capable of supporting 75 lb  
(34 kg). 
 
Prepare Range hood for mounting into cabinet
Mark the locations for the four mounting screws on the  
 
hood cabinet as shown below.
Using a ⅛” (3 mm) drill bit, drill the 4 holes. 
 
 
  
 
 
 
 
 
       
A
B
C
D
E
F
 
 
 
 
 
 
 
Mark the cutout for the rectangular clearance hole for the  
 
upper range hood motor housing as shown.
Using a jigsaw or keyhole saw, cut out the rectangular 
 
clearance hole for the upper range hood housing. 
 
 
 
 
 
 
 
1.
2.
3.
4.
A. Centerline
Mounting 
holes
A. Centerline
MOUNTING HOLE DIMENSIONS
Hood
Insert
DIM B
DIM C
DIM D
DIM E
DIM F
EAR628SS
5½” (14 cm)
11” (28 cm)
12
5
32
” (30.9 cm)
24
5
16
” (61.8 cm)
Ø1/8” (3mm)
EAR134SS
6” (15.5 cm)
10
1
16
” (25.6 cm)
14
15
16
” (38 cm)
29
13
16
” (75.8 cm)
Ø1/8” (3mm)
EAR140SS
6” (15.5 cm)
10
1
16
” (25.6 cm)
14
15
16
” (38 cm)
29
13
16
” (75.8 cm)
Ø1/8” (3mm)
EAR146SS
6” (15.5 cm)
10
1
16
” (25.6 cm)
14
15
16
” (38 cm)
29
13
16
” (75.8 cm)
Ø1/8” (3mm)
UPPERHOOD MOTOR HOUSINGS DIMENSIONS
Hood
Insert
DIM B
DIM C
DIM D
DIM E
EAR628SS
4
13
/
16
” (12.2 cm)
12
7
8
” (32.7 cm)
11¼” (28.57 cm)
22½” (57.15 cm)
EAR134SS
4
13
/
16
” (12.2 cm)
12
7
8
” (32.7 cm)
14” (35.56 cm)
28” (71.12 cm)
EAR140SS
4
13
/
16
” (12.2 cm)
12
7
8
” (32.7 cm)
14” (35.56 cm)
28” (71.12  cm)
EAR146SS
4
13
/
16
” (12.2 cm)
12
7
8
” (32.7 cm)
14” (35.56 cm)
28” (71.12  cm)
Hood spacer