Make Electrical Power Supply 
Connection to Hood Insert 
 
 
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
 
Disconnect power.
Locate terminal box inside of the hood insert. 
 
 
 
 
 
Use UL listed wire connectors and connect black wires  
 
(B) together.
Use UL listed wire connectors and connect white wires  
 
(A) together. 
 
 
 
Electrical Shock Hazard 
Electrically ground blower. 
Connect ground wire to green and yellow ground wire in 
terminal box. 
Failure to do so can result in death or electrical shock.
 
Connect green (or bare) ground wire from home power  
 
supply to the green/yellow ground wire (D) in terminal  
 
box using UL listed wire connectors.
Install terminal box cover.
Check that all light bulbs are secure in their sockets.
Reconnect power. 
1.
2.
3.
4.
5.
6.
7.
8.
A
B
C
D
E
G
F
A.White wires
B. Black wires
C. UL listed wire connectors
D. Green, bare or yellow/green wires
E.Home power supply
F. UL listed or CSA approved ¹⁄2” (1.3 cm) strain relief
G. Ground Wire tab
B
A
A. Wiring Box Connector
B. Hood Insert Connector
Complete Installation and 
Check Operation
 
Install grease filters. See the “Cleaning” section.
Check operation of the Hood Insert blower and lights.  
 
See the “Hood Insert Use” section. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
If the hood insert does not operate, check to see 
 
whether a circuit breaker has tripped or a hous 
 
hold fuse has blown.
Disconnect power supply and check that the  
 
wiring is correct. 
NOTE: To get the most efficient use from your new hood 
insert, read the “Hood Insert Use” section.
1.
2.
3.
4.
A. Halogen lights
B. Halogen light switch
C. Blower control switche 
D. Grease filter handle
E. Grease filter
F.  Filter Spacer (Only for EAR628SS model)
A
A
B C
A
A
F
D
E