Problem:
Cause/Remedy
The appliance does not operate 
after connection to the power line:
• Check if there is power in the socket and if the appliance is 
switched on.
Cooling system operates 
continuously without intermittent 
stoppages:
• Ambient temperature too high.
• Frequent opening of the door, door open too long.
• Door not closed properly (something caught in door gasket,
sagging door, check gasket sealing, etc...).
• Excessive quantity of fresh food inserted at one time.
• Refrigerator sensor (A) is blocked with fresh food. Free 
the sensor and allow air to circulate around it.
• Check air circulation for suffi cient cooling of the compressor, 
and clean the condenser.
Excessive ice formation at 
the rear interior wall of the 
refrigerator:
•  Frequent opening of the door, door open too long.
•  Inserting hot food in the refrigerator.
•  Food or dish is touching the rear interior panel of the 
refrigerator.
•  Bad door sealing; clean or replace the gasket if dirty or 
damaged.
Build-up of ice or frost in the
freezer interior may be a result of
the following:
• Door opened too frequently or too long.
• Door not properly closed.
• Poor door sealing.
• If the seal is dirty or damaged, clean or replace it.
Water dripping from the 
appliance:
•  Drain outlet is clogged, drain water drips past the collection 
groove.
•  Clean the clogged outlet using plastic straw.
•  Thaw thick ice deposits manually (see chapter Defrosting).
Red light is fl ashing (freezer 
compartment only):
•  Frequent opening of the door, door open too long.
•  Door not closed properly (something caught in door gasket, 
   sagging door, damaged gasket, etc...).
•  Excessively long power failure.
•  Excessive quantity of fresh food inserted at one time.
Diffi cult door opening:
• If you attempt to open the door of the freezer immediately 
after it has been closed you may experience resistance. 
This happens because a certain quantity of cold air 
escapes from the appliance through the open door and is 
replaced by warm ambient air. Cooling of such air creates 
negative pressure (vacuum) and suction, which prevents 
easy opening of the door. This is normalized after several 
minutes and you can open the door with ease.