Avocent EMS1000P Manuel D’Utilisation
![Avocent](https://files.manualsbrain.com/attachments/1745b7305b1466f317a1e3758fe59db007c7f435/common/fit/150/50/aca1e56c2a6c1350aaa3828827f45d5a1f3fc416fb7ace1a379314a7e912/brand_logo.jpeg)
26
Emerge EMS Installer/User Guide
Chapter 3: Operations
27
To Adjust Skew
Your chances of achieving a successful skew adjustment will be improved if you do the following:
• Ensure that you have a clear view of one or both display screens,
• Display a suitable RGB test pattern, either the
Your chances of achieving a successful skew adjustment will be improved if you do the following:
• Ensure that you have a clear view of one or both display screens,
• Display a suitable RGB test pattern, either the
• Use a screwdriver of an appropriate size to adjust the dials,
• Begin with both skew dials in their neutral positions - if the unit has been previously used and
• Begin with both skew dials in their neutral positions - if the unit has been previously used and
1. Turn the
SKEW RG
dial clockwise or counterclockwise until you observe that the red and
green colors are aligned.
2. Turn the
SKEW GB
dial clockwise or counterclockwise until you observe that the green and
blue colors are aligned.
3. Your actions in step 2. may alter the Red/Green alignment. If so, go back to the
SKEW RG
dial
and turn it clockwise or counterclockwise until you observe that the Red and Green colors are
aligned, at which point all of the colors will be aligned.
0
(no compensation)
Skew RG
Skew GB
0
(no compensation)
Delay
RED
Delay
GREEN
Delay
GREEN
Delay
BLUE
Figure 3.8: The two skew compensation dials showing how they affect
each of the colors. When delay is applied to a color, it moves further
to the right of the screen.