Overview of the Test Set’s Built-In Tools
Using the Spectrum Analyzer
Using the Spectrum Analyzer Mask
The spectrum analyzer mask consists of two adjustable limit lines. 
They show the upper and lower limits of spectral occupancy. You can 
choose to set and display either upper or lower limits for the mask, or 
both. When the mask is turned on, it continuously monitors the signal 
spectrum with respect to these limits and indicates a failure when the 
spectrum exceeds these limits. A “Fail” message, along with a beep (if 
activated), indicates a failure. “Pass” is displayed if the signal remains 
within the limits of the mask.
Displaying the Spectrum Analyzer Mask
1. On the SPEC ANL screen, set the 
Controls
 field to 
MASK
. (See 
 fo
instructions.)
2. Set the 
Display
 field to show the mask on the screen, and to indicate 
which limits you want to measure against.
Upper Only
Lower Only
Both
Setting this field to 
Off
 turns off the mask and the pass/fail 
indicator. 
3. Set the Mask Type field to the type of mask you want to measure 
against.
• Fix sets the mask to absolute limits defined in the 
#Pts
EditPoint
Lvl
, and 
Freq
 fields. When using fixed limits a 
change in the center frequency or level may cause the mask to 
move beyond the viewable area of the screen.
Rel
 sets the mask relative to the center frequency and reference 
level defined in the 
Center Freq
 and 
Ref Lvl
 fields on the 
spectrum analyzer’s 
Main
 controls menu. 
You can define two masks, one fixed and one relative and switch 
between the two using this field.