Agilent Technologies 8935 series e6380a Manuale Utente

Pagina di 320
152
Chapter 5
C:\Spk\Ref\RefGuideRevE\CdmascrnE2.fm
CDMA Measurements - Screens and Control Fields
Control Fields for CDMA Measurements
Analyzer (CDMA analyzer)
The 
Analyzer
 field controls three functions: 
Arm Meas
 arms the CDMA analyzer. The CDMA analyzer needs to 
be armed only when 
Single
 (see below) is selected. 
Single/Cont
 selects between “single” measurements and 
“continuous” measurements. 
— When 
Single
 is chosen, you must arm each measurement by 
selecting the 
Arm Meas
 field (see above). 
— When 
Cont
 (continuous) is chosen, measurements are 
automatically armed. 
The default selection is 
Cont
.
Disarm
 disarms the CDMA analyzer during single operation. To stop 
continuous measurements, select 
Single
. Selecting 
Disarm
 does not 
prevent the analyzer from being re-armed during continuous 
measurements 
Screens on which this field is present
CDMA ANALYZER
Analyzer (code domain analyzer)
This field is used to arm or disarm measurements when making a 
single measurement (does not affect continuous measurements). 
Selecting 
Disarm
 stops the analyzer during a single measurement.
 for more information.
Screens on which this field is present
COD DOM (Code Domain Analyzer): main controls menu
Anl Dir 
This field is used to select the type of signal (forward or reverse link) to 
analyze.
Fwd
 sets the analyzer to look for base station transmitter data 
(forward link). 
Rev
 sets the analyzer to look for mobile transmitter data (reverse 
link). 
Default selection: 
Fwd
Screens on which this field is present
CDMA ANALYZER