Agilent Technologies 8935 series e6380a Manuale Utente

Pagina di 320
228
Chapter 7
C:\Spk\Ref\RefGuideRevE\Cnfgscrn.fm
Configuration - Screens and Control Fields
Control Fields on the Configuration Screens
Base Freq (User Defined)
The base frequency field sets the RF generator reference for channel 0 
(zero) when the 
RF Chan Std
 field is set to 
USER-DEF
, and the 
RF 
Display
 field is set to 
Chan
Channel frequencies are calculated using the following formula:
Channel N = Base Frequency + (N)(Channel Spacing)
The Base Frequency is calculated using the following formula:
Base Frequency = Channel 1 Frequency 
 Channel Spacing
For example, if your multi-channel radio’s lowest receive channel 
frequency is 870.030 MHz and the system channel spacing is 30 kHz, 
you would enter 
870 MHz
 in this field. You would also use the 
Chan 
Space
 and 
(Gen)-(Anl)
 fields to tell the Test Set where other transmit 
and receive channel frequencies are in relation to the base frequency, 
and whether or not the system is duplex. 
For more information see the following related topics:
 
Operating Considerations
The value of this field is only used if the 
RF Display
 field is set to 
Chan
and the 
RF Chan Std
 field is set to 
USER-DEF
Screen(s) Where Field is Present
INSTRUMENT CONFIGURE
Beeper 
This field changes the audio beeper volume by selecting the desired 
level from a list of choices (Off, Quiet, Loud). The beeper always beeps 
when the instrument is turned on, regardless of this setting. 
Operating Considerations
The beeper alerts you any time a message is displayed. Since a message 
may be removed from the screen before you notice it, it is better to leave 
the beeper on to alert you to errors during operation. 
The beeper’s volume setting is retained when the instrument is turned 
off.