Agilent Technologies 8935 series e6380a Manuale Utente
Chapter 7
229
Configuration - Screens and Control Fields
Control Fields on the Configuration Screens
Screen(s) Where Field is Present
INSTRUMENT CONFIGURE
Call
•
Originate
places a call using the dialing sequence entered in the
Number to Call
field. This field is inactive when the
Modem Mode
field is set to
Disable
.
•
Disconnect
causes the modem to disconnect from the call in
progress. It also cancels any pending call origination
Retries
. This
field is inactive when the
Modem Mode
field is set to
Disable
.
Screen(s) Where Field is Present
MODEM CONFIGURE
Chan Space (User Defined)
This field specifies the RF channel spacing when the
RF Display
field
is set to
Chan
, and the
RF Chan Std
field is set to
USER-DEF
.
For example, entering
25 kHz
causes a 25 kHz spacing between each
channel. If the receive frequency for channel 1 is 150.500 MHz, channel
2’s receive frequency would be 150.525 MHz.
2’s receive frequency would be 150.525 MHz.
Operating Considerations
The value of this field is only used if the
RF Display
field is set to
Chan
,
and the
RF Chan Std
field is set to
USER-DEF
.
For more information see the following related topics:
Screen(s) Where Field is Present
INSTRUMENT CONFIGURE
CDMA Std
This field allows you to specify the CDMA standard to be used in Code
Domain measurements. Select
Domain measurements. Select
IS-95 only
to show Power, Timing and
Phase using IS-95 protocol. Select
IS-2000
to show Power, Complex
Power, Power & Noise and Fast Power Synchronize, using the IS-2000
protocol.
protocol.
For more information on the results of this selection see: