DC Current (uA and mA - Autoranging):
Range Resolution
Accuracy
Burden
Voltage
Voltage
Overload Protection
400uA
0.1uA
1%+2
<0.25V
0.5A / 250V Fast Blow Fuse
4000uA
1uA
1%+2
<1V
0.5A / 250V Fast Blow Fuse
40mA
10uA
1%+2
<0.25V
0.5A / 250V Fast Blow Fuse
400mA
100uA
1%+2
<1.5V
0.5A / 250V Fast Blow Fuse
10A
10mA
1.2%+2
0.35V
10A / 250V Fast Blow Fuse
Resistance (Autoranging):
Range Resolution
Accuracy
Test Voltage
Overload Protection
400
ȍ 0.1
ȍ 0.75%+2
<1.5VDC
600Vrms
4K
ȍ 1
ȍ 0.75%+2 <1.5VDC
600Vrms
40K
ȍ 10
ȍ 0.75%+2 <1.5VDC
600Vrms
400K
ȍ 100
ȍ 0.75%+2
<1.5VDC
600Vrms
4M
ȍ 1K
ȍ 0.75%+2
<1.5VDC
600Vrms
40M
ȍ 10K
ȍ
1.2%+3
<1.5VDC
600Vrms
Continuity Beeper:
Range
Active Range
Test Voltage
Overload Protection
Under 40
ȍ <1.5V
600Vrms
Diode Tester:
Range Resolution Accuracy Test Current Test Voltage
Overload Protection
1mV 1%+
2 <1mA <3.2V
600Vrms
Frequency (Autoranging):
Range Resolution
Accuracy
Sensitivity
Overload
Protection
4 KHz
1Hz
0.1%+1
<300mVpp
600Vrms
40KHz 10Hz
0.1%+1
<300mVpp
600Vrms
400KHz 100Hz
0.1%+1
<300mVpp
600Vrms
4MHz 1KHz
0.1%+1
<3Vpp
600Vrms
40MHz 10KHz
0.1%+1
<3Vpp
600Vrms
NOTES