Monarch 110 Manuale Utente
MODEL 110 AUTORANGING DIGITAL MULTIMETER
3
Accuracy specification: ± ([…% of reading] + [… number of least
significant digits]) at 18°C to 28°C (64°F to
82°F) at less than 80% RH
82°F) at less than 80% RH
Temperature coefficient: 0.1
x Specified Accuracy/°C
Electromagnetic compatibility:
Vac and Aac only:
RF field = 3V/m
Total accuracy:
Specified accuracy + 2% of range
Digital display:
4000 counts
Sampling
rate: Twice per second
Analog display:
42 segments
Sampling
rate: 20 times per second
Overrange indication:
Displays ‘OL’ when value exceeds range
selected
selected
Auto Power Off:
30 minutes after last operation
Power requirement:
Two 1.5V AAA batteries
Battery life:
500 hours typical. Low battery indication.
Safety:
600V CAT II, Regulation EN61010:
Part 1:1993
Part 1:1993
Operating conditions:
xOperating Temperature and Humidity: 0°C - 40°C (32°F - 104°F)
Below 80% RH Non-condensing
xStorage Temperature and Humidity: -10°C - 60°C (14°F - 140°F)
Below 70% RH Non-condensing
xInstallation category II
xPollution Degree 2
xIndoor use only
xAltitude up to 2000 meters (6500 feet)
xPollution Degree 2
xIndoor use only
xAltitude up to 2000 meters (6500 feet)
Dimensions:
150
u72u35mm (5.9u2.8u1.4 in)
Weight:
Approx. 220g (7.8 oz)
Accessories:
Test Leads, Spare Fuse (0.5A/250V),
Batteries, Instruction Manual
Batteries, Instruction Manual
MODEL 110 AUTORANGING DIGITAL MULTIMETER
12
7.0 Service and Maintenance
7.1 Service
and
Repair
Other than replacing the batteries and/or fuses, this instrument is
NOT user serviceable. Consult qualified service and repair
personnel for internal servicing.
NOT user serviceable. Consult qualified service and repair
personnel for internal servicing.
7.2 Maintenance
Periodic maintenance is limited to cleaning of the external case
with a damp cloth and mild detergent. Do not use harsh abrasives
or solvents in cleaning this instrument.
with a damp cloth and mild detergent. Do not use harsh abrasives
or solvents in cleaning this instrument.