System Limitations 
While this system is an advanced-design security system, it does not offer guaranteed protection 
against burglary, fire, or other emergency. Any alarm system, whether commercial or 
residential, is subject to compromise or failure to warn for a variety of reasons.  For example: 
•  Intruders may gain access through unprotected openings or have the technical sophistication 
to bypass an alarm sensor or disconnect an alarm warning device. 
•  Intrusion detectors (e.g., passive infrared detectors), smoke detectors, and many other sensing 
devices will not work without batteries or if the batteries are not put in properly.  Devices 
powered solely by a main power supply will not work if their main power supply is cut off for 
any reason, however briefly. 
•  Signals sent by wireless transmitters may be blocked or reflected by metal before they reach 
the alarm receiver.  Even if the signal path has been recently checked during a weekly test, 
blockage can occur if a metal object is moved into the path. 
•  A user may not be able to reach a panic or emergency button quickly enough. 
•  While smoke detectors have played a key role in reducing residential fire deaths, they may 
not activate or provide early warning for a variety of reasons in as many as 35 percent of all 
fires.  Some of the reasons smoke detectors used in conjunction with the system may not work 
are as follows:  Smoke detectors may not sense fires that start where smoke cannot reach the 
detectors, such as in chimneys, in walls, on roofs, or on the other side of closed doors.  Smoke 
detectors also may not sense a fire on another level of a residence or building.  A second-floor 
detector, for example, may not sense a first-floor or basement fire.  Moreover, smoke detectors 
have sensing limitations. No smoke detector can sense every kind of fire every time.  In 
general, detectors may not always warn about fires caused by carelessness and safety hazards 
like smoking in bed, violent explosions, escaping gas, improper storage of flammable 
materials, overloaded electrical circuits, children playing with matches, or arson.  Depending 
on the nature of the fire and/or the location of the smoke detectors, the detector, even if it 
operates as anticipated, may not provide sufficient warning to allow all occupants to escape in 
time to prevent injury or death. 
•  A passive infrared motion detector can detect intrusion only within the designed ranges as 
diagrammed in its installation manual.  Passive infrared detectors do not provide volumetric 
area protection.  They do create multiple beams of protection, and intrusion can be detected 
only in unobstructed areas covered by the beams.  They cannot detect motion or intrusion that 
takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or 
windows.  Mechanical tampering, masking, painting, or spraying of any material on the 
mirrors, windows, or any part of the optical system can reduce their detection ability.  Passive 
infrared detectors sense changes in temperature; however, as the ambient temperature of the 
protected area approaches the temperature range of 90º to 104º Fahrenheit (32º to 40º 
Celsius), the detection performance can decrease.