Ironman Fitness V2 Manuale Utente

Pagina di 56
46 
 
The complete system should be tested at regular intervals. We suggest testing it once every 
fortnight or at least once per month.  
Real Time Clock battery 
Your  Watchguard  Digital  is  equipped  with  a  real  time  clock  for  logging  alarm  events  and 
billing  information.  The  battery  for  the  Real  Time  Clock  is  located  inside  the  Main  Control 
Unit.  Replacing  or  removing  this  battery  will  result  in  incorrect  event  logging  and  billing.  
Please  DO  NOT  attempt  to  remove/replace  this  battery.  If  it  ever  fails,  the  unit  must  be 
returned to the manufacturer for replacement. 
 
Real-Time Clock Battery Specifications 
 
Battery Type 
CR2025 Lithium 
Capacity 
160mAH 
Voltage 
3V 
 
Main Control Unit Backup Battery 
The backup battery is used for providing normal alarm operation during times when the 
normal AC mains power is unavailable (such as during a temporary short-term blackout). 
The backup battery automatically charges when the Main Control Unit is connected to the 
AC adapter. The system has a self-test function to test the backup battery; it will report a low 
backup battery on disarm, by beeping 10 times and will also notify the user through the event 
logging through the SecureNet monitoring system. 
 
Manual Battery Test:
 Disconnect the Power Supply and ensure the system will arm and 
disarm from back up battery power only. If the system failed the test, then reconnect the 
power supply and allow it to charge for three hours before performing another test. Failing 
the test again will confirm that the battery needs to be replaced.   
 
Main Control Unit Battery Replacement Procedure 
 
Turn off the alarm system by turning the key switch to the ‘OFF’ position. 
Undo the unit and remove the cover. 
Replace with a new battery of the same type.  
 
Replacement batteries are available by calling 1300 653 533. 
  
Main Control Unit Backup Battery Specifications 
 
Battery Type 
Rechargeable NiMH (Nickel Metal 
Hydride) 
Capacity 
200mAH 
Voltage 
9V (8.4V)