Installation  (for qualified installers only)
© Travis Industries
4040830
100-01143
Electrical Line Connection
a
b
Insert the sheathed cable from the power source through 
this cable clamp.  Once the wires are attached, tighten 
the clamp to secure the  cable.
Replace the 
cover removed 
in step "a".
Attach the common (white), ground (exposed or green) 
wires, and hot (black) wires from the power source to the 
electrical connector (attached to the fireplace).
c
d
Standard 
Screwdriver
Remove the cover 
from the fireplace 
junction box.
1/4" Nutdriver
WARNING: Make sure power is 
off from the power lead before 
conducting any wiring.
Electrical 
Connector
Optional Electrical Line Location
Remove the two screws securing the 
electrical inlet (save these screws).
Remove the cover plate on the bottom of the 
fireplace (save these nuts).
Position the electrical inlet assembly over the 
hole in the baseplate of the fireplace and 
secure using the screws removed in step “b”.
a
b
c
Position the cover plate over the 
electrical inlet hole on the right side 
of the fireplace and secure using the 
nuts removed in step “a”.